1. Check that the nitrogen gas bottle valve is closed of
Hydraulic breaker/hammer;
2. Connect the high pressure hose to the
hydraulic hammer nitrogen gas bottle;
3. Connect the
high pressure hose to the charging valve;
4. Inspecting the gas pressure;
5. Turn the gas bottle valve wheel clockwise to allow gas to enter the hose;
6. Turn the charging valve wheel to allow the gas to pressurize the accumulator chamber;
7. Pay close attention to the gauge so the seals are not stretched by application of excessive gas pressure(DO NOT EXCEED THE MAXIMUM GAS PRESSURE DURING CHARGING);
8. Turn the charging valve wheel counterclockwise to prevent any more gas entering the
hydraulic breaker;
9. Turn the release valve counterclockwise to relieve gas in the high pressure hose;
10. Disconnect the charging valve from adapter;
11. Install adapter cap on to adapter of
hydraulic hammer.